{"product_id":"mrcool-hyper-heat-2nd-gen-24k-btu-2-ton-18-3-seer2-heat-pump-condenser-and-ducted-air-handler-central-24-hp-230b00-o","title":"MRCOOL Hyper Heat 2nd Gen 24K BTU, 2 Ton, 18.3 SEER2 Heat Pump Condenser and Ducted Air Handler (CENTRAL-24-HP-230B00-O)","description":"\u003ch3\u003eMRCOOL Hyper Heat 2nd Gen 24K Complete System\u003c\/h3\u003e\n\u003cp\u003eBring heating and cooling to a central ducted home with the MRCOOL Hyper Heat 2nd Generation 2-ton split system. SKU \u003cstrong\u003eCENTRAL-24-HP-230B00-O\u003c\/strong\u003e combines the outdoor heat pump, matching multi-position indoor air handler and MRCOOL smart thermostat. It uses R-454B refrigerant and variable-speed inverter technology.\u003c\/p\u003e\n\u003ch3\u003eWhat's Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor condenser:\u003c\/strong\u003e CENTRAL-24-HP-C-230B00-O.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor air handler:\u003c\/strong\u003e MVP-24-HP-MUAH-230A00-O.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMRCOOL Smart Thermostat\u003c\/strong\u003e for central-system control.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSold separately:\u003c\/strong\u003e refrigerant line set and optional auxiliary electric heat kit. The manufacturer's brochure identifies flare-connection stub pipes and copper nuts as included. Installation materials and electrical work depend on the application.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVariable-speed DC inverter operation adjusts output to changing heating and cooling demand.\u003c\/li\u003e\n\u003cli\u003eSide-discharge condenser with a painted galvanized-steel cabinet.\u003c\/li\u003e\n\u003cli\u003eAir handler supports upflow, downflow, horizontal-left and horizontal-right installation.\u003c\/li\u003e\n\u003cli\u003eSlide-out blower and self-diagnostic display simplify service access.\u003c\/li\u003e\n\u003cli\u003eOptional compatible R-454B No-Vac Quick Connect line sets and electric heat kits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem SKU:\u003c\/strong\u003e CENTRAL-24-HP-230B00-O\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 840255589208\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal size:\u003c\/strong\u003e 24K class \/ 2 ton\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated cooling \/ heating capacity:\u003c\/strong\u003e 23,000 \/ 24,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePublished efficiency:\u003c\/strong\u003e Up to 18.3 SEER2; 11.7 EER2; 10.0 HSPF2, Region IV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerant:\u003c\/strong\u003e R-454B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor electrical supply:\u003c\/strong\u003e 208\/230V, 60Hz, single-phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor minimum circuit ampacity \/ maximum fuse:\u003c\/strong\u003e 19A \/ 20A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir-handler supply:\u003c\/strong\u003e 115\/208\/230V, 60Hz, single-phase; verify installation configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLiquid \/ suction connection:\u003c\/strong\u003e 3\/8 in. \/ 3\/4 in.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondenser dimensions, W × D × H:\u003c\/strong\u003e 35.04 × 13.46 × 26.50 in.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondenser net weight:\u003c\/strong\u003e 102.29 lb\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir-handler dimensions, W × D × H:\u003c\/strong\u003e 21.02 × 17.52 × 45.00 in.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir-handler net weight:\u003c\/strong\u003e 105.6 lb\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFilter size:\u003c\/strong\u003e 16 × 20 × 1 in.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePerformance values follow MRCOOL's 2nd-generation brochure for the matched 24K combination. Final equipment selection, load calculation, electrical protection, clearances and duct design must follow the unit nameplates, current manuals and applicable codes.\u003c\/p\u003e\n\u003ch3\u003eInstallation \u0026amp; Warranty\u003c\/h3\u003e\n\u003cp\u003eThis is an R-454B central ducted system. Traditional refrigerant-line installation requires a licensed HVAC professional. An optional approved No-Vac line set does not remove electrical, code or site-specific requirements. Use a qualified electrician for electrical work and follow the current installation manual.\u003c\/p\u003e\n\u003cp\u003eMRCOOL's limited warranty lists ten years of compressor, parts and labor coverage for the original owner, subject to its terms. The installing company is responsible for the first 90 days of labor; manufacturer labor coverage begins on day 91. Exclusions include freight, routine maintenance, diagnostics and refrigerant. Review the full warranty below.\u003c\/p\u003e\n\u003ch3\u003eManuals \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.mrcool.com\/wp-content\/dox_repo\/mc-vp-HH-CDU-im-um-en-01.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; owner's manual: VersaPro \/ Hyper Heat R-454B (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.mrcool.com\/wp-content\/dox_repo\/mc-cd-hh-gen-2-br-en-01.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHyper Heat 2nd Generation brochure and specifications (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/doxrepo.mrcool.com\/mc-cd-hh-gen-2-perf-specs-en-01.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDetailed performance tables (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.mrcool.com\/wp-content\/dox_repo\/mc-HH-CDU-wr-en-01.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCentral Ducted Hyper Heat limited warranty (English \/ French PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/mrcool.com\/wp-content\/dox_repo\/mc-smt-wt-um-en-01.pdf\" target=\"_blank\" rel=\"noopener\"\u003eMST04 smart thermostat installation \u0026amp; owner's manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.mrcool.com\/wp-content\/dox_repo\/mc-vp-hh-hk-im-um-en-01.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOptional VersaPro \/ Hyper Heat heat-kit manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/support.mrcool.com\/hc\/en-us\/articles\/34891164932116-Central-Ducted-24K-Hyper-Heat-Condenser-2-ton-230v-2nd-Gen\" target=\"_blank\" rel=\"noopener\"\u003eManufacturer 24K Hyper Heat support, certification and document links\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/support.mrcool.com\/hc\/en-us\/articles\/34796485056788-VersaPro-24K-Central-Ducted-Air-Handler-2-Ton-230v\" target=\"_blank\" rel=\"noopener\"\u003eManufacturer 24K air-handler support and compatible accessories\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"MRCOOL","offers":[{"title":"Default Title","offer_id":50248423571746,"sku":"CENTRAL-24-HP-230B00-O","price":3291.18,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0820\/7669\/6866\/files\/mc-vp-2gen-01-4000px.webp?v=1755641575","url":"https:\/\/www.homeandheat.com\/products\/mrcool-hyper-heat-2nd-gen-24k-btu-2-ton-18-3-seer2-heat-pump-condenser-and-ducted-air-handler-central-24-hp-230b00-o","provider":"Home \u0026 Heat","version":"1.0","type":"link"}